DDFI-2 – "Current Errors Byte 2"

TypeBitfield
Size1 Byte
Logged as"CDiag2"

Description:

Current trouble codes, byte 3

Bitfields:

Bit-No.Meaning
0Tachometer output short to ground
1Tachometer output short to supply voltage
2Fuel pump short to ground
3Fuel pump short to supply voltage
4Injector 2 short to ground/broken wire
5Injector 2 short to supply voltage
6Coil 2 short to ground/broken wire
7Coil 2 short to supply voltage

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (raw_value * scale) + translate


Please double-check all information from this site before using them!