| Type | Table | 
|---|---|
| Offset | 352 (0x0160) | 
| Size | 8 Bytes | 
| Element Size | 1 Byte | 
| Elements | 8 | 
| Columns | 2 | 
| Rows | rows | 
| Data Scale | 0.250000 | 
| Data Translate | 0.000000 | 
| Data Units | Degrees | 
| Axis Scale | 1.000000 | 
| Axis Translate | 0.000000 | 
| Axis Units | Degrees C | 
Description:
WOT spark advance reduction
The spark advance (data) against engine temperature (axis) in WOT condition. The interpolated value is subtracted from the value of the timing table. This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.
 Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate
Please double-check all information from this site before using them!